Solutions · By need
Modernize legacy software
The system still runs the business, but every change is slow and risky. Our approach to legacy software modernization starts with an audit and continues with incremental replacement. There is no big-bang rewrite and no day on which everything switches at once.
The context
Legacy software modernization usually lands on the desk of an operations or IT manager, not a developer. The system might be a PHP application from another era, an Access database that grew into the company's back office, or a desktop program that only runs on one old machine. It works, people depend on it every day, and the developer who wrote it is gone. The common mistake is to wait for a crisis, such as a server that fails or a security patch that is never released, and then decide under pressure.
After 15 years on production systems, our position is simple: the old code is documentation. It holds pricing exceptions, edge cases in invoices and rules that nobody wrote down anywhere else, so we read it before we judge it. The work is ordered by risk, not by elegance. Backups and a reproducible deployment come before any new feature, and the first module to be replaced is the one that causes the most trouble, not the one that is most fun to rewrite.
What makes it hard
1
Every change is risky
There are few tests, and the people who wrote the code have moved on. A small fix in one place breaks something elsewhere.
2
Outdated technology
The framework or language version is no longer supported. Security patches stop, and it gets harder to hire developers who want to work on it.
3
The pull of a full rewrite
Starting from scratch looks cleaner, but the business cannot stop for it. Full rewrites tend to run long, and they miss rules that live only in the old code.
How we work on it
Step 1
Audit
We read the code, the database and the deployment, and talk to the people who use the system. You get a written report: what is sound, what is dangerous, what to do first.
Step 2
Protect before changing
We put the system under version control, automated deployment and backups, and add tests around the critical flows. From then on, every change can be checked.
Step 3
Replace piece by piece
New modules take over one function at a time, next to the old system. Both run in parallel and share data until the old part can be switched off.
Step 4
Migrate data and retire the old parts
Data is moved with scripts that are rehearsed on copies and verified. Each old part is removed once nothing depends on it.
What you end up with
A written audit with priorities you can act on.
A system that stays in service during the whole migration.
Supported technology, automated tests and repeatable deployments.
Documentation of the business rules that were hidden in the old code.
Services involved
Frequently asked questions
Why not rewrite everything from scratch?
Because the business has to keep running, and the old code contains rules nobody remembers. Replacing one part at a time lets each step be checked in production before the next one. A full rewrite also delivers nothing until the very end, while a step-by-step replacement improves something with every release.
Can you work on code we did not write and that has no documentation?
Yes. That is what the audit is for. We read the code, trace the main flows and write down how the system really works before changing it.
Will users have to change the way they work?
Only when a screen is replaced, and then one screen at a time. The data stays the same, so teams keep working during the move. Where a new screen does change a routine, we test it first with the people who use it most and adjust it before it reaches everyone.
What drives the cost of modernizing a legacy system?
Three things weigh most: how much of the system has to be replaced, how messy the data is, and how many other systems depend on it. A clean database with few integrations is far easier to migrate than years of inconsistent records feeding the accounting software and a supplier portal. The audit gives you a cost per step, so you can fund the most urgent parts first and decide on the rest later.
How long does it take to modernize a legacy system?
There is no single answer, because the work is a series of steps rather than one project. The first steps, the audit and a safety net of backups, tests and automated deployment, are short and already reduce risk. After that, the pace depends on the number of modules, the state of the data and how much time your team can give to checking each replaced part. You can also stop after any step and still have a system that works.
Do we have to move to the cloud as part of the modernization?
No. Modernizing the code and moving the hosting are two separate decisions, and doing both at once adds risk to every step. The system can stay on your own servers, move to a private server, or go to AWS or Google Cloud, depending on cost, regulation and who will operate it. Because each service ends up in a Docker container, the hosting can also change later without touching the code.
Design, build and ship your project
Describe it in three lines. We reply with specific questions and a first take on how to proceed.